Recognition and diagnosis1In acute critical care practice, the fastest LV systolic assessment is qualitative or semiquantitative, using myocardial thickening and endocardial inward motion in the LV short-axis view to estimate systolic function.
2A simplified bedside classification of LV function is hyperdynamic, normal, moderately depressed, or severely depressed.
3Qualitative classification into normal, mildly reduced, moderately reduced, or severely reduced follows integration of endocardial motion and wall thickening from multiple views.
4Standard transthoracic planes used for qualitative LV systolic assessment include parasternal long-axis, parasternal short-axis, apical four-chamber, apical two-chamber, and apical long-axis views; on TEE, equivalent views from high TEE and transgastric positions are used.
5Normal LV geometry is described as bullet-shaped in long-axis views and circular in short-axis views; abnormal geometry may include apical rounding, apical asymmetry, or regional dilation.
6LV basal dimension measured in 2D at end-diastole in the PLAX view provides a rapid assessment of LV size.
7LV wall thickness of the anteroseptal and basal inferolateral walls is measured at end-diastole in the PLAX view; normal thickness is generally <1.0 cm and severe thickening is >1.6 cm.
8Normal LV wall thickening is >30%.
9For linear dimension measurements, end-diastolic measurements are made at QRS onset and end-systolic measurements at minimum chamber size just before aortic valve closure.
10LVIDd is measured at or immediately before the peak of the R wave, and LVIDs at the end of the T-wave; this timing applies to 2-D and M-mode measurements.
11Fractional shortening uses LV end-diastolic and end-systolic diameters measured in parasternal long- or short-axis windows, 1 cm apical to the septal aortic attachment, perpendicular to the long axis, bisecting the chordae tendineae; on TTE it is measured in the parasternal long-axis view just below the level of the mitral valve tips.
13Normal fractional shortening is >30 - 45%, but it has limited clinical use, assesses myocardial function in only one plane and only 2 walls (inferior and anterior in transgastric short axis and transgastric bicaval TEE views), does not reflect global LV shortening when regional wall motion abnormality is present, and may overestimate overall LV function.
14FAC is derived by tracing the LV endocardial border, excluding papillary muscles, in the transgastric mid-papillary short-axis plane at end-diastole and end-systole to obtain LVEDA and LVESA, then calculating FAC = (LVEDA − LVESA)/LVEDA × 100%.
15A normal FAC value is >35%.
16LVEF represents stroke volume as a percentage of LVEDV and is calculated as LVEF = (LVEDV - LVESV)/LVEDV × 100%.
17Simpson’s biplane method involves tracing the LV in systole and diastole in paired orthogonal apical long-axis views and is regarded as the best measurement of EF; it is the 2D method to be routinely assessed on all diagnostic echo studies, with 3D EF recommended when feasible depending on image quality.
18Both the area-length formula and Simpson’s method reliably estimate LVEF.
193D echocardiography provides more accurate assessment of LV volumes and EF than 2D echocardiography and is the modality of choice for that purpose, although it depends more on gray-scale image quality and has lower temporal resolution unless multi-beat acquisition is used.
20EPSS is measured in the PLAX view with M-mode across the distal tip of the anterior mitral leaflet.
21EPSS >7 mm is consistent with reduced EF.
22EPSS >1 cm may indicate LVEF <40%, with sensitivity 69% and specificity 91%; EPSS may not reflect cardiac function in valvular disease such as mitral stenosis or prosthesis or aortic regurgitation, where abnormal leaflet movement can give a falsely high EPSS despite normal LVEF, or in septal hypertrophy, and multiple measurements are needed in atrial fibrillation.
23LV stroke volume can be estimated by measuring LVOT diameter and LVOT VTI, using ALVOT = DLVOT^2 x 0.785 and SVLVOT = ALVOT x VTI LVOT.
24CO = SV x HR, as in the example DLVOT 1.9 cm, area 2.8 cm2, VTI 25 cm, SV 70 mL, HR 80 bpm, and CO 5600 mL/min or 5.6 L/min.
25For LVOT measurements, the LVOT diameter is measured from inner edge to inner edge at the aortic annulus in mid-systole with maximal leaflet separation, perpendicular to the LVOT.
26LVOT VTI is obtained with pulsed-wave Doppler in the apical long-axis or 5-chamber view, with the Doppler gate parallel to and centered in the LVOT at the level where diameter was measured.
27For VTI, the PWD sample volume is placed just proximal to the aortic valve, the velocity curve should be smooth with a well-defined peak, and any angle between the Doppler beam and LVOT can underestimate VTI and therefore stroke volume.
28Because LVOT area is constant for an individual patient, changes in VTI reflect changes in stroke volume, and ventilator-cycle variation in VTI may be used to assess preload sensitivity.
29Assessment of regional LV wall motion uses wall thickening and inward wall motion during systole for each segment.
30Standard segmental wall anatomy includes 17 segments.
31Qualitative segmental grades are normal, hypokinetic, akinetic, or dyskinetic.
32Akinesia is defined as absent movement or contraction, hypokinesia as reduced movement or contraction, and dyskinesia as outward bulging in systole instead of inward shortening.
33Aneurysm is visible deformation in both systole and diastole with excessive wall thinning.
34For quantitative regional assessment, abnormal segmental contractility is defined as wall thickening <50% or wall excursion <5 mm.
35Mitral annular plane systolic excursion and tissue Doppler S′ are described as measures of LV longitudinal function.
36Longitudinal function may be assessed by MAPSE using M-mode and by the S′ wave using tissue Doppler imaging or strain.
37Annular displacement by M-mode or peak mitral annular systolic velocity s′ by tissue Doppler can provide LV longitudinal systolic indexes that are less dependent on image quality.
38LV strain describes the relative change in myocardial length from end-diastole to end-systole and is expressed as a percentage.
39Negative strain values indicate shortening and positive values indicate elongation.
40GLS is usually measured from apical four-chamber, two-chamber, and long-axis views, and normal longitudinal strain is typically about 20%, expressed as a negative number.
41A segment shortening from 2 cm to 1.6 cm yields longitudinal strain of -20%, while thickening from 1 to 1.4 cm yields radial strain of +40%.
42A GLS example is -10.6%.