Recognition and diagnosis1In critically ill patients, bedside echocardiography can be used urgently to assess LV function, RV function, pericardial effusion/tamponade, preload and fluid responsiveness, and valve lesions while resuscitation is ongoing.
2Main critical care indications listed for echocardiography include hypotension or hemodynamic instability, assessment of volume status, acute chest pain with suspected myocardial infarction and nondiagnostic complementary tests, suspected myocardial infarction complications, evaluation of biventricular systolic function during acute coronary syndrome, respiratory failure or hypoxemia of uncertain cause, pulmonary embolism, severe deceleration injury or chest trauma, suspected valvular or structural heart disease, suspected infective endocarditis, and procedural guidance such as pericardiocentesis.
3A basic bedside study is described using four standard views: parasternal long axis, parasternal short axis, apical four-chamber, and subcostal.
4Echocardiographic hemodynamic evaluation is organized around dimensions, flows, and derived parameters rather than simply seeking surrogates of invasive measurements.
5Both TTE and TEE are described as versatile tools for hemodynamic assessment in ICU patients.
6Intravascular pressures such as left atrial pressure, LV end-diastolic pressure, and systolic pulmonary artery pressure are not directly measured by echocardiography, but Doppler data can be used with the modified Bernoulli equation to calculate specific pressures.
7Right atrial pressure is assessed indirectly by ultrasound evaluation of the IVC, not by direct measurement.
8For cardiac output estimation, Doppler echo applies the flow equation in which volume equals cross-sectional area multiplied by velocity-time integral: Volume = CSA × VTI.
9Stroke volume is obtained from the product of LVOT area and LVOT VTI, and cardiac output is then derived from stroke volume and heart rate.
10One practical formula given for systemic vascular resistance is SVR = (MAP − RA pressure) (mm Hg)/CO (L/min), with SVR expressed in Wood units.
11For serial measurements, following LVOT VTI alone is recommended, assuming LVOT diameter remains constant.
12Accurate Doppler blood-flow measurement depends on a parallel intercept angle between the ultrasound beam and blood flow direction; nonparallel alignment underestimates velocity and can distort hemodynamic measurements.
13CW Doppler records signals along the full beam path and is used for high velocities such as stenosis or regurgitation, whereas pulsed Doppler samples a specific site but only within a limited velocity range.
14For LV systolic assessment, qualitative regional wall motion is graded as hyperdynamic, normal, hypokinetic, akinetic, or dyskinetic; specific definitions are based on endocardial motion and wall thickening in systole.
15A formal LVEF measurement with the modified Simpson’s method is more objective and strongly recommended, but in critical care it is prone to error from apical foreshortening, especially during mechanical ventilation, and from poor endocardial definition.
16LVEF of 54% is given as the cutoff for normal LV function.
17Other values give normal EF as >55%.
18Normal fractional shortening is 30–45%.
19A high LVEF can be misleading when regurgitant lesions are present, and about 50% of acute heart failure patients are described as having preserved LVEF.
20Visual estimation of EF is said to be reliable only when performed by an expert echocardiographer-intensivist; with basic TTE competence, measurement using endocardial border excursion in apical four-chamber and apical two-chamber views with averaging is preferred.
21Three-dimensional echocardiography can calculate end-diastolic volume, end-systolic volume, and EF, and high correlation of 3D-derived volumes with magnetic resonance imaging has been reported.
22For LV diastolic assessment, normal transmitral inflow is described with E-wave velocity 60–80 cm/s, deceleration time 140–200 ms, A-wave velocity 20–60 cm/s, and normal E/A ratio 1–2.
23Impaired ventricular filling with increased filling pressures is associated with a reduced E/A ratio.
24E/E′ ≥15 is associated with elevated filling pressures.
25E/E′ >15 indicates high PCWP and E/E′ <8 is consistent with normal, near-normal, or decreased PCWP in septic shock.
26E/A >2 is associated with a pulmonary artery occlusion pressure (PAOP) >18 mmHg, with a positive predictive value of 100%.
27Color M-mode E/Vp >1.5 is also associated with elevated filling pressures.
28LV filling pressure or pulmonary capillary wedge pressure is obtained by combining transmitral flow velocity and tissue Doppler relaxation velocity.
29Doppler assessment of forward mitral flow is load-dependent, and age significantly affects LV filling pattern interpretation.
30For volume status and hypovolemia, criteria include LV end-diastolic diameter <25 mm, systolic obliteration of the LV cavity, and LV end-diastolic area <5.5 cm2/m2.
31In true hypovolemia both systolic and diastolic LV areas are small, whereas in vasodilation with hypotension only the systolic LV area is small.
32Normal LV end-diastolic area is 13 ± 2 cm2/m2 and severe hypovolemia is LVEDA <6 cm2/m2 with end-systolic obliteration of the LV cavity.
33Volume responsiveness is defined as the ability to increase stroke volume by ≥15% after volume loading.
34Preload estimation can be altered by pathophysiologic states, mechanical ventilation, and patient position, and attention to the IVC, RA, RV, and LV is recommended.
35IVC assessment is described as commonly used for preload estimation, best obtained in the subcostal view.
36IVC-based assessment is less reliable with low tidal volumes, low lung compliance, spontaneous breathing, and excessive probe pressure on the abdomen.
37ESICM guidelines on circulatory shock and hemodynamic monitoring state that measuring the IVC end-expiratory diameter may help guide fluid therapy and resuscitation, but it must not be used by itself to predict whether a patient will respond to fluids.
38For dynamic fluid responsiveness, after passive leg raising, an increase in LVOT VTI >12% is highly sensitive and specific for volume responsiveness.
39In mechanically ventilated patients, ΔVTI >10% predicts fluid responsiveness.
40ΔVpeak >12% predicts fluid responsiveness during positive-pressure ventilation.
41Different dynamic thresholds are given: a peak velocity variation index >12% and a VTI variation >18% can predict a sufficient increase in cardiac output.
42Beat-to-beat ΔVpeak is generally evaluated over five consecutive respiratory cycles.
43Pulse pressure variation and stroke volume variation are not very helpful in arrhythmia and lung-protective ventilation; the ESICM guidelines on circulatory shock and hemodynamic monitoring recommend PPV, and suggest SVV, for assessing fluid responsiveness in ventilated shock patients who have no spontaneous breathing activity and whose tidal volume is ≥ 8 mL/kg, and suggest against relying on PPV alone when spontaneous breathing activity is present and the tidal volume is < 8 mL/kg.
44Pericardial effusion is identified by an echo-free space between parietal and visceral pericardium on parasternal, apical, and/or subcostal views.
45Effusion size in tamponade is categorized by diastolic thickness: small up to 10 mm, moderate 10–20 mm, and large >20 mm.
46Small effusions <25 mL are usually posterior and seen only during systole, while larger effusions surround the heart throughout the cardiac cycle.
47A swinging heart may be seen with large effusions.
48Tamponade findings include RA collapse in systole and RV collapse in diastole.
49Collapse occurs at the lowest-pressure point of the cycle, specifically right atrial systolic collapse and RV diastolic collapse.
50Late diastolic right atrial collapse is an early, highly sensitive sign of tamponade, especially when it lasts for more than one-third of the cardiac cycle, but its specificity is only moderate at about 82% because brief RA collapse can also occur with elevated intrathoracic pressure; sustained RA collapse remains a strong indicator of tamponade.
51Another view holds that the most sensitive 2D sign is RV collapse during diastole.
52These views therefore differ on which chamber-collapse sign is the most sensitive.
53Tamponade-associated IVC findings include dilation and reduced respiratory variation.
54Doppler findings supporting tamponade include increased respiratory variation in intracardiac flow, decreased mitral forward flow during inspiration, increased tricuspid velocity during inspiration, and changes in atrial and ventricular inflow profiles with breathing.
55Tamponade may occur with only a moderate effusion, and the size of the effusion does not determine tamponade potential.
56In critical care, tamponade remains a clinical diagnosis supported by echo findings, and it may occur even without the characteristic echocardiographic signs.
57Post-cardiotomy or iatrogenic collections may be small, localized, and compress a single chamber or vessel; in such cases TEE is described as performing better than TTE.
58RV assessment is part of routine bedside hemodynamic echo in unstable patients.
59Echo can serially evaluate both RV and LV hemodynamic status and track response to interventions such as fluids or drug therapy.
60In acute pulmonary embolism, echocardiography is emphasized during the initial assessment of unstable patients, and unequivocal RV pressure-overload signs may support emergency reperfusion treatment when clinical probability is high and no other clear cause is present.
61Septal leftward shift and reversal of septal curvature are illustrated as signs of isolated RV pressure overload.
62The trans-tricuspid CW Doppler signal is described as allowing indirect estimation of RV pressure, which equals systolic pulmonary artery pressure if there is no pulmonic stenosis.
63In septic shock, LV systolic dysfunction may be masked early by reduced afterload and may become evident after volume resuscitation and norepinephrine infusion.
64In this context, echo may help distinguish cardiogenic shock with high PCWP from septic shock with normal, near-normal, or decreased PCWP using E/E′ thresholds of >15 versus <8.
65Speckle tracking can reveal subtle LV and RV dysfunction not detected by conventional TTE or TEE, and LV strain abnormalities may exist despite unchanged EF.
66Repeated examination after volume expansion is advised when assessing diastolic function, to avoid excessive fluid load.