Persistent circulatory instability
An adult ICU patient remains unstable after initial sepsis resuscitation. Assess, request measurements as needed, treat, and reassess over clinical time.
Loading bedside...
The ICU vital-sign screen and compact PiCCO case monitor are separate. Drag to rotate, wheel to zoom, right-drag to pan.
Bedside observations · SIMULATED
ABP mmHg—
MAP mmHg—
HR /min—
SpO₂ %—
Urine mL/h—
Clinical hour—
Clinical timeline
Assess and investigate
Laboratory samples
No reported sample.
Hemodynamic decisions
Virtual acquisition assumes access already present. Catheter placement and indicator injection remain on HOLD.
Treatment
Commands affect later simulated hours. Actions do not imply a validated dose response.
Clinical time and disposition
Latest finding
Educational debrief
PiCCO · hemodynamic case monitorOriginal educational interface · synthetic case values · no certified device behavior
MONITORING NOT REQUESTEDNOT CALIBRATEDSIGNAL QUALITY UNVERIFIED
Pulse contour · continuous case trend
Clinical time H0
CO · L/min—
CI · L/min/m²—
SV · mL—
SVI · mL/m²—
SVR · dyn·s/cm⁵—
SVRI · dyn·s·m²/cm⁵—
ICU bedside context · separate vital-sign monitor
ABP / MAP — mmHg · HR — /min · SpO₂ — %
Calibrated hemodynamic trends over simulated time
Hour
CI L/min/m²
SVI mL/m²
SVRI dyn·s·m²/cm⁵
CO L/min
MAP mmHg
Measurement and calibration state
Choose and interpret monitoring in the context of the case.
Pulse-contour values are case-model trends after virtual calibration. Technical signal concerns withhold these estimates; no catheter manipulation is taught.
Thermodilution · sampled
No sample
CO TD · L/min—
CI TD · L/min/m²—
GEDI (GEDVI) · mL/m²—
ELWI (EVLWI) · mL/kg—
PVPI · unitless—
No thermodilution sample.
These sampled values remain fixed until another virtual measurement. GEDVI does not establish fluid responsiveness.
Recorded synthetic samples
Hour
CI TD L/min/m²
GEDI mL/m²
ELWI mL/kg
PVPI
Measurement validity · explicit limits
SVV / PPV:
CVP 8 mmHg and BSA 1.9 m² are authored case inputs for derived indices, not new measurements.
Contractility indices · model boundary
dPmx, CPI, CFI and GEF are not produced by this case model. Interpret the authored echo, flow and perfusion response instead; no contractility index is inferred.
Perfusion and alarms
Lactate: no reported sample
PiCCO patient connections · external schematicOriginal educational drawing · procedural placement and internal catheter tips HOLD
The separate venous and arterial locations follow Getinge's PiCCO connection scheme. This view identifies external connections only; catheter placement, transducer setup, waveform fidelity and indicator injection are not simulated.