Management1There is no standardized VA ECMO weaning process, so strategy should be individualized to the original indication for support.
2Before VA ECMO weaning, myocardial recovery, hemodynamic stability, and resolution of the primary cause of cardiogenic shock should be confirmed, with weaning started once the patient has been stable on minimal or no inotropic support for more than 24 hours and echocardiography shows sufficient myocardial recovery; readiness should also include stable hemodynamics on no or low-dose vasoactive agents, a stable rhythm, good arterial-line pulsatility, MAP >60 mmHg, appropriate LV venting if the LV is distended, stable or recovering organ function, and multidisciplinary agreement on prognosis.
3VA ECMO weaning should be considered only after adequate cardiac recovery on echocardiography, resolution of the primary pathology, and hemodynamic stability on no or minimal ionotropic support for at least 24 h.
4The common VA ECMO method is gradual blood-flow reduction with cardiac assessment at each stage.
5Flow is reduced in 0.5–1 L/min steps or by percentages such as 66% and 33% of baseline flow, either over 10–15 min at each step or gradually over several hours, with the aim of allowing cardiorespiratory adaptation and assessment.
610–15 min is adequate to demonstrate LV and RV changes when echocardiography is being used during stepwise assessment.
7The final VA ECMO low-flow assessment is placed at about 0.5–1 L/min or 1–1.5 L/min.
8The low VA ECMO flow is maintained for about 40–60 min while progressively augmenting ventilatory support for rising pulmonary blood flow.
9VA ECMO weaning should only be considered after echocardiographic evidence of adequate cardiac recovery, resolution of the original pathology, and at least 24 hours of hemodynamic stability with no or minimal ionotropic support; flow should be reduced gradually with cardiac function checked by echocardiography, and if the patient then remains stable at 1 L/min for 30–60 min, decannulation can be considered.
10In VA ECLS, severe lung dysfunction argues against standard removal: if the PaO2/FiO2 ratio is <100 mmHg while the ECLS gas-flow FiO2 is 21%, conversion from V-A to V-V ECLS should be considered, and if weaning criteria are still not met the patient should remain on full support for more recovery time, or, if recovery is not realistic, be evaluated for longer-term support or end-of-life planning.
11VA ECMO weaning is typically down to 2–2.5 L/min with close invasive and echocardiographic observation, and if flows <2 L/min are desired, the weaning trial should be brief at <1 h with denser anticoagulation considered.
12At each VA ECMO flow level, echocardiography and cardiac function monitoring are used, and signs to abort the wean include hemodynamic instability, ventricular insufficiency on echocardiography, rising blood lactate, or a significant fall in ScvO2; if these appear, full support should be restored and the weaning process retried later.
13During VA ECMO support, hemodynamic assessment focuses on native cardiac function using echocardiography, cardiac output, and SvO2, while adequacy of tissue perfusion is followed by correction of metabolic acidosis, decreasing lactate, and urine output.
14Continuous SpO2 monitoring is used as a guide to arterial oxygenation, and in VA ECMO placing the probe on the right-hand fingers helps assess oxygenation to the brain and myocardium.
15During VA ECMO, frequent ABG analysis may be required during nonpulsatile flow.
16Distal perfusion monitoring in VA ECMO includes limb color and warmth compared with the contralateral side, with routine Doppler assessment of distal pulses.
17Dark urine during ECMO should prompt evaluation for hemolysis with lactate dehydrogenase, serum bilirubin, haptoglobin, aspartate aminotransferase, alanine aminotransferase, and plasma-free hemoglobin.
18Some centers use pulmonary vasodilators such as inhaled nitric oxide to reduce RV afterload during or shortly after VA ECMO weaning, which may facilitate successful separation.
19Some institutes administer levosimendan 0.1 μg/kg/min to improve systolic and diastolic function.
20Intra-aortic balloon pump use during VA ECMO restored pulsatility and reduced LV afterload in one study, but no study has assessed its value specifically during VA ECMO weaning.
21One alternative VA ECMO approach is pump-controlled retrograde trial off, during which oxygen is removed from the circuit, the distal perfusion cannula is disconnected, and a heparin flush line is connected to distal perfusion to avoid thrombus formation; if hemodynamics stay stable on low-to-moderate vasoactive support, echocardiography shows good biventricular contractility, and lactate does not worsen, the patient is considered suitable for weaning. During PCRTO, anticoagulation is essential to prevent circuit thrombosis, and because this technique creates an AV shunt with systemic flow steal, the degree of shunting must be regulated to avoid RV failure.
22For VV ECMO, weaning can start when natural lung gas exchange is adequate at moderate ventilator settings, described as FiO2 <0.5–0.6 with a low PEEP value.
23As lung function improves and the native lung contributes more to oxygenation, extracorporeal blood flow is progressively reduced, whereas in purely hypercapnic patients who started with low blood flow, sweep gas flow is altered instead.
24Many centers decrease FdO2 before switching off sweep gas to limit oxygen-related toxicity on the native lung; the effect of stepwise FdO2 reduction at constant sweep on systemic oxygenation depends on the ratio of extracorporeal blood flow to cardiac output and on the venous admixture of the native lung.
25Stopping sweep gas completely removes all oxygen delivery from the circuit, so sweep should be paused only in patients who have already tolerated oxygen weaning.
26Several VV ECMO sources describe reducing sweep gas flow to 0 and then performing a trial off while keeping circuit blood flow running initially.
27ECMO FGF is weaned until it is off, and cannulae are generally removed after a period of gas flow (usually 2–24 hours). Trial-off duration for VV ECMO is quite variable between centres: the EOLIA trial used 1 hour, at least 2–3 h is recommended, and other groups have used 30 min. Some centres assess for 12–24 h or longer off sweep gas, especially in complex patients or with longer ECMO runs. A duration of 6–12 h has also been used. The trial can last from 1 to 12 hours, or longer if needed.
28When the patient is on controlled ventilation for a VV ECMO trial, ventilator settings should be adjusted to values acceptable off ECMO, and ventilator FiO2 <70% is specifically advised.
29An ELSO chapter on VV ECMO weaning recommends augmenting ventilation from ultra-protective to lung-protective levels, keeping FiO2 30%–60%, PEEP at least 5–10 cmH2O, and RR ≤30 breaths/min.
30In volume control, increasing VT by 1–2 mL/kg PBW up to 6–8 mL/kg PBW with Pplat ≤28 cmH2O is recommended, or in pressure control/pressure support, driving pressure should be increased to no more than 15–20 cmH2O while keeping delivered VT in the 6–8 mL/kg PBW range.
31A separate ELSO overview of ventilator practice on VV ECMO describes ultra-protective targets of PEEP ≥10 cmH2O, VT no more than 4–6 mL/kg PBW, Pplat <25 cmH2O, RR 4–15 breaths/min or spontaneous breathing, and FiO2 30%–50% but as low as possible.
32Before stopping VV ECMO gases, the patient can be placed on ARDSNET-type settings of 6 cc/kg, plateau pressure <30 cm H2O, FiO2 50%, and PEEP 10, with RR increased to maintain acceptable minute ventilation.
33VV ECMO weaning can be done by reducing circuit flow (typically by 0.5–1.0 L/min) to <2.5 L/min, setting the ventilator to VT ≤6 mL/kg, peak airway pressure <30 cm H2O, and FiO2 to keep oxygen saturation >90%, then decreasing sweep to <1 L/min; however, for weaning and decannulation in neonatal respiratory failure, reducing ECLS flow and sweep is often used instead of, or as a prelude to, a trial-off, and readiness for trial-off is suggested only after a repeat arterial blood gas at 20 minutes shows PaCO2 35–45 mmHg, VT 6 mL/kg can be achieved with PIP 25, and there is no PaO2 fall or hemodynamic instability.
34VV ECMO flows are usually kept above 2 L, with decannulation when the patient tolerates 2 to 2.5 L/min with 21% oxygen and 1 L of sweep, whereas many centers reduce flow to 1–2 L/min before VV decannulation; however, 1–2 L is only a bare minimum for safety and, more commonly, centers do not reduce flow below 2–3 L.
35A more general minimal-flow approach applicable to both respiratory and cardiac support is about 750–1000 mL/min in an adult 3/8 inch circuit, whereas some centers instead keep adult flow >3000 mL/min and assess lung recovery by weaning sweep-gas FiO2 rather than circuit flow.
36If a VV ECMO trial off fails, signs include hypoxia, hypercapnia, respiratory distress, and hemodynamic instability, and the response is to return to full support and investigate causes such as fatigue, worsening pathology, new sepsis, fluid overload, or inadequate ventilator settings.