Durable left ventricular assist devices1A durable continuous-flow LVAD depends on preload and is sensitive to afterload, so it needs a working right ventricle to fill it.
2It is considered for selected patients with advanced HFrEF (NYHA IIIB–IV) who depend on intravenous inotropes or temporary support, as a bridge to transplant, a bridge to candidacy or destination therapy.
3Survival after implantation has reached 83.0% at 1 year and 51.9% at 5 years.
4On the INTERMACS scale, profiles 1–3 are likely to live longer with a device, profile 4 might, and profiles 5–7 are unlikely to gain over best medical care; older age, frailty, established multi-organ failure, fixed pulmonary vascular resistance and shock at implantation all worsen survival.
5Patients on non-pulsatile LVADs have no palpable peripheral pulses. Arterial line monitoring early after LVAD implant, considers a mean arterial pressure of 75 to 90 mm Hg reasonable in hospitalized patients to reduce the risk of stroke, and notes that a Doppler may be required for blood pressure assessment in patients without an arterial line.
6Bleeding is common, with acquired von Willebrand disease and gastrointestinal or intracranial haemorrhage, alongside pump thrombosis and driveline infection.
7Patients with an LVAD stay on warfarin, with or without an antiplatelet drug depending on the device, aiming for an INR of 2 to 3.
8In LVAD patients, gastrointestinal bleeding (20% within 1 year) is related to anticoagulation, acquired von Willebrand factor deficiency and gastrointestinal angiodysplasias. EGD or push enteroscopy is the initial investigation of choice. Anticoagulant and antiplatelet drugs are held for haemodynamically significant bleeding, with possible reversal of anticoagulation if the INR is elevated and the bleed is clinically unstable.
9Pump thrombosis can show as haemolysis, so LDH and haptoglobin are checked, and aiming for lower INR values has been linked with more pump thrombosis.
10Prompt treatment of infection lowers the chance of seeding; when the source is unclear, treat it as a driveline infection. Antibiotics should span Gram-negative and Gram-positive organisms and suit the hospital’s known flora and resistance patterns.
11New right heart failure points to pulmonary hypertension, pulmonary embolism or a pump speed set too high, and new left heart failure to pump thrombosis, cannula (inflow or outflow) obstruction, or motor or battery failure.
12Too little preload empties the ventricle so its walls collapse onto the inflow, giving low-flow or suction alarms, reduced flow and ventricular arrhythmias.
13Chest compressions are controversial; if given, they are done carefully so the device is not dislodged.
14The pump's hum is listened for first and a restart of the device is tried, ventilating without compressions at first, and compressions are started if the restart fails or definitive care is delayed.
15Compressions may be given to an unresponsive patient who is not perfusing, and all modern devices tolerate external defibrillation and cardioversion.