Recognition and diagnosis1A normal sinus rhythm is defined by a P wave before every QRS complex and a QRS complex after every P wave, a regular rhythm at a rate of 60–100/min, and P waves upright in leads I, II, aVF and V5–V6; the sinus P waves are identical in morphology and upright in leads I and aVF.
2If these sinus-rhythm criteria are not met, an arrhythmia is present. It also notes that an arrhythmia can persist even when the criteria are met, since the problem may lie in impulse conduction, for example bundle branch block or first-degree AV block.
3Normal heart rate is 60–100 bpm; bradycardia is <60 bpm and tachycardia is >100 bpm.
4Abnormally rapid heart rates are defined as >100 bpm and abnormally slow heart rates as <50 bpm when discussing arrhythmia diagnosis.
5The first distinction is framed as tachyarrhythmia >120/min versus bradyarrhythmia <60/min.
6At the usual ECG paper speed of 25 mm/s, a small square is 0.04 s and a large square 0.20 s; in a regular rhythm, 1500 divided by the count of small squares between QRS complexes gives an estimate of heart rate.
7The count-off sequence “300-150-100-75-60-50” is another method for estimating rate from the number of large boxes between QRS complexes.
8The ECG analysis of tachyarrhythmia begins with whether the QRS is narrow or wide, and examples of wide rhythms are VT and supraventricular tachycardia with aberrancy or preexcitation, and of narrow rhythms PSVT, AF or flutter, and atrial tachycardia.
9If QRS width is <0.12 seconds, the rhythm originates above the bifurcation of the bundle of His and may arise from the sinoatrial node, atria, or atrioventricular node.
10If QRS duration is >0.12 seconds, the rhythm may arise from ventricular myocardium or be supraventricular with aberrant conduction such as bundle branch block.
11Narrow QRS is ≤120 ms or three small squares, and broad QRS is the contrasting category.
12For rhythm regularity, inspection of an adequate-length rhythm strip and comparison of successive R-R intervals is emphasized, including use of dividers or marked paper to detect subtle irregularity.
13If R-R intervals are totally irregular (irregularly irregular) and QRS morphology stays constant, atrial fibrillation is the most likely rhythm.
14On examination, an irregular pulse with no pattern also suggests AF.
15In an ECG example of AF, the baseline is undulating and the QRS complexes are irregularly irregular, with a ventricular rate of 105 beats/min.
16AF is described as having atrial activity variable in amplitude, shape, and timing, usually best seen in V1 when visible, with atrial activity <200 ms and therefore >300 bpm, together with an irregular ventricular response.
17Regular R-R intervals can still occur during AF if concomitant AV block or AV junctional or ventricular tachycardia is present.
18Most atrial tachycardias and flutters have atrial cycle lengths of ≥200 ms, although AF may show slower atrial cycle lengths in patients taking antiarrhythmic drugs.
19Atrial flutter with 2:1 block appears as a regular narrow-complex tachycardia, and flutter should be considered whenever the heart rate is fixed at 150.
20Atrial flutter has ventricular rate 150 and atrial rate 250–350.
21AF has no P waves and ventricular rate 130–200; atrial tachycardia has rate 120–180, PSVT 130–240, VT >100 and accelerated idioventricular rhythm 60–100.
22Abnormally slow heart rates may be caused by sinus bradycardia or sinoatrial or AV block, and diagnosis is made by assessing rate, regularity, and configuration of P waves and QRS complexes, the relation of P waves to QRS complexes, and the PR interval.
23Irregular rhythms may be caused by atrial or ventricular premature beats, AF with slow ventricular response, or incomplete second-degree sinoatrial or AV block.
24If the basic rhythm is regular but intermittently irregular, extrasystoles (ectopic beats) may be disturbing an otherwise regular underlying rhythm. If the QRS complex of ectopic beats is narrow (< 0.12 seconds), a supraventricular beat is likely (for example, from atrial muscle or the atrioventricular node), whereas broad-complex ectopic beats may be ventricular in origin or supraventricular ectopic beats with bundle branch block.
25Determining atrial activity is important but may be difficult or impossible because P waves can be absent or obscured by QRS complexes or T waves, and one should not guess unless atrial activity is certain.
26Multiple leads are optimal in stable patients, whereas a single lead is often adequate in unstable patients. Recording a 12-lead ECG, if possible, may allow P waves to be picked out in one or more leads even when the initial monitoring lead shows them poorly. Lead V1 often shows atrial activity clearly, including sinus P waves and atrial fibrillation; sinus P waves are generally clear in lead II, and atrial flutter shows best in the inferior leads. Mapping the P waves with calipers may be needed to establish P wave presence and their relationship to the QRS complexes, and an esophageal lead can help if P waves are hard to see.
27A twelve-lead ECG recorded during the rhythm abnormality, and also in normal sinus rhythm, is described as the most useful first diagnostic test.
28If the patient is clinically stable, obtain a 12-lead ECG and a continuous rhythm strip in leads that best show atrial activation, such as V1, II, III, and aVF.
29A 12-lead ECG should be examined for evidence of conduction abnormalities such as preexcitation or bundle branch block, or for signs of structural heart disease such as prior myocardial infarction. The 12-lead ECG is also read for acute ischaemia, previous infarction, ventricular aneurysm or LV hypertrophy; for abnormalities of rate, rhythm, conduction or SND; for the PR interval, QRS duration and QT interval; and for changes of electrolyte abnormalities.
30Comparison with baseline ECG can reveal subtle QRS differences caused by superimposed atrial and ventricular depolarization, and prior tracings are often valuable.
31For paroxysmal dysrhythmias, the onset and termination of the rhythm may contain particularly useful clues and should be inspected carefully and preserved.
32Loose leads, muscle contraction, shivering, tremors and other movement can produce artifactual findings on a monitor, rhythm strip, or 12-lead ECG. These pseudodysrhythmias mimic serious dysrhythmias, including ventricular fibrillation. ECG artifacts may also mimic tachyarrhythmias; small notches that occur at regular intervals and coincide with pulse activity help to tell them apart from real tachyarrhythmias, and the correct diagnosis can be made by identifying QRS complexes at regular intervals.
33ECG appearance alone should not be relied on without clinical context when pseudodysrhythmia is possible.
34Ventricular fibrillation can be diagnosed when no distinct QRS complexes are identifiable.
35For ventricular tachycardia, an example tracing shows rate 150 beats/min, widened QRS complexes, and AV dissociation, with atrial rate 73 beats/min.
36If cannon A waves in the JVP are irregular, this may suggest AV dissociation and possible VT.
37Extremely rapid ventricular rates >200 bpm suggest either an accessory pathway or VT.
38A symptomatic wide-complex tachycardia in a patient with known ischemic heart disease is described as much more often VT than a supraventricular dysrhythmia.
39The Brugada ECG criteria include four features of VT, any one of which makes the diagnosis of VT. The rhythm must be regular for them to be used, because irregularity suggests atrial fibrillation with altered conduction. The sequential criteria for a regular wide-complex tachycardia are: no RS complex in any precordial lead; an RS interval greater than 100 msec, measured from the start of R to the deepest part of the S wave; AV dissociation; and finally VT-specific morphologic criteria.
40Only if all Brugada criteria are absent can SVT be diagnosed by that approach.
41When applying the Brugada approach, the Brugada ECG criteria include four features of VT, any one of which makes the diagnosis of VT; the rhythm needs to be regular for them to be used, and the criteria are less reliable in patients receiving class I agents.
42If bundle branch block is present in sinus rhythm but has a different morphology or axis from that during tachycardia, the tachycardia is likely ventricular in origin.
43If delta waves are present and have the same polarity as the tachycardia QRS complexes, the likely diagnosis is Wolff–Parkinson–White syndrome with antidromic AVRT or AF.
44In dual-chamber pacing systems, a pacemaker-mediated tachycardia usually appears as paced QRS complexes occurring at, or close to, the maximal tracking rate of the device. Terminating the rhythm by placing a magnet, with no recurrence once the magnet is taken away, supports this diagnosis. Atrial fibrillation with maximal conduction through the pacemaker is the alternative to consider, and there the tachycardia comes back after the magnet is taken away.
45Longer-duration rhythm recording is often necessary because a standard 12-lead ECG samples fewer than 20 complexes in less than a minute, whereas Holter recording acquires >100 000 complexes in 24 hours.
46Holter ECG can diagnose intermittent (paroxysmal) arrhythmias, provided the symptomatic arrhythmia actually reappears during the monitoring time. Twenty-four-hour ambulatory electrocardiography captures transient events: a short burst of tachycardia, an occasional pause in rhythm, or intermittent ST-segment shifts; the technique is named Holter electrocardiography after its inventor.
47Duration differs slightly: Holter monitoring is described as 24 hours, 24 or 48 hours, and usually 24–72 hours.
48Event recorders are used to document symptomatic transient arrhythmias that occur infrequently. A recording device may be kept for several days or weeks until the arrhythmia has been captured; event monitors may be worn for 1 to 3 months; and a loop recorder worn over 1 to 2 months may record rhythms occurring about once every 4 weeks.
49A loop recorder is worn by the patient and records the cardiac rhythm continuously; when the patient activates it or autodetection triggers it, a rhythm strip is stored that includes several minutes of earlier data. Some monitors are triggered only by the patient, who holds the device against the chest when symptoms occur. When symptoms appear, the patient triggers the monitor, which records the rhythm both before and after the event.
50An implantable loop recorder is a very small event recorder that can be placed under the skin and triggered either by events or by a magnet; durations range from several months with subcutaneous implantation of a loop recorder to nonstop rhythm recording for up to 3 years with such a device.
51Programmable pulse limits for implanted loop recorders are specified, such as below 40 beats/min and above 180 beats/min.
52All monitors and recorders (Holter, event and loop) aim to link an arrhythmia with the patient's symptoms. A time-marked diary of patient-reported symptoms compared with the heart rhythm recording is key to deciding whether the symptoms are due to arrhythmia. In circumstances in which the diagnosis of a suspected arrhythmia is particularly elusive, an insertable loop recorder can be used to match symptoms with the cardiac rhythm.
53Stress ECG, a continuous ECG recorded during physical exercise, can provoke arrhythmias induced by stress, or yield important information on raised sinus node rates (chronotropic competence) and on how accessory pathways conduct.
54An electrophysiologic study is an invasive procedure used to investigate unclear arrhythmias and in patients with syncope. Beforehand, the arrhythmia should always be documented by noninvasive methods, so that induced arrhythmias can be matched with the clinical ECG tracings.
55An EPS is almost always indicated to document and characterise ventricular tachyarrhythmia, and the baseline study should be done first while the patient is off all antiarrhythmic drugs. Inducible sustained ventricular arrhythmias at EPS carry a worse outlook, with a 5-year SCD risk of 32% against 24% when no arrhythmia is inducible, and are an indication for an implantable defibrillator.
56Echocardiography helps evaluate structural heart disease associated with arrhythmia, and transthoracic echocardiography is described as useful for identification of structural heart disease in atrial fibrillation, cardiomyopathies, or congenital heart disease.
57CXR and transthoracic echocardiography can provide evidence of structural heart disease that makes ventricular arrhythmias more likely.
58In unexplained ventricular arrhythmias, transthoracic echocardiography should be performed to rule out structural heart disease, and urgent echocardiography is advised in sudden hemodynamic worsening or uncontrolled arrhythmias.