Recognition and diagnosis1Hemodynamic monitoring observes cardiovascular function to determine whether adequate organ perfusion is being maintained.
2Detection of circulatory insufficiency integrates clinical, hemodynamic, and laboratory data, and clinical signs may be nonspecific or absent despite shock.
3Clinical bedside indicators of tissue hypoperfusion include altered mental status, dyspnea, angina, cold extremities, prolonged capillary refill time, and decreased urine output, but these signs indicate impaired perfusion rather than its cause.
4The purposes of hemodynamic monitoring are to define an individual’s cardiovascular state, determine whether adequate organ perfusion is being maintained, detect cardiovascular insufficiency and contributing causes, and guide treatment through choice of therapy, assessment of response, determination of therapeutic endpoints, and detection of complications.
5Principal hemodynamic biomarkers are arterial pressure, central venous pressure, pulmonary artery pressure, pulmonary artery occlusion pressure, and cardiac output.
6Current systems provide pressure and flow measurements that act only as inexact surrogates of preload, contractility, and afterload, derived from systemic or pulmonary arterial pressure, filling pressure or volume indices, SV or CO, and tissue-wellbeing markers.
7MAP relates to CO and SVR by MAP = CO × SVR, so hypotension may reflect low CO, low SVR, or both.
8CO = HR × SV, and SV is influenced by preload, contractility, and afterload.
9SVR is traditionally calculated as (MAP - right atrial pressure)/CO and is usually expressed in dynes s/cm5, though Wood units are also used.
10The same calculation in Wood units is SVR = MAP - RA pressure (mm Hg)/CO (L/min).
11Clinicians are described as poor at estimating cardiac output from clinical signs alone, and identifying the cause of suspected low CO requires further hemodynamic evaluation.
12For shock states, typical patterns are: distributive shock has increased CO after fluid replacement, low or normal filling pressure, decreased SVR, and increased or normal SvO2; cardiogenic shock has decreased CO, increased filling pressure, increased SVR, and decreased SvO2; hypovolemic shock has decreased CO, decreased filling pressure, increased SVR, and decreased SvO2; obstructive shock has decreased CO, decreased transmural filling pressure, increased SVR, and decreased SvO2.
13Septic shock specifically involves absolute hypovolemia, relative hypovolemia from generalized vasodilatation coexisting with zones of vasoconstriction, early myocardial dysfunction, and inadequate oxygen extraction due to intracellular abnormalities.
14A low diastolic arterial pressure can indicate decreased vascular tone in septic shock, and DAP < 40 mmHg is stated to trigger immediate vasopressor therapy and to suggest vasopressor initiation; DAP below 40 mm Hg may cause myocardial ischemia, is often due to reduced vascular tone especially in tachycardia, and with HR ≥100 bpm predicts higher mortality.
15An arterial catheter is recommended for all septic shock patients, with MAP individualized around 60–65 mmHg; higher levels may be needed in older previously hypertensive patients and lower levels may suffice in younger patients. For initial resuscitation in adult septic shock, an initial MAP target of 65 mm Hg over higher targets is recommended, kept in practice within a reasonable range of about 5 mm Hg, and an initial MAP range of 60–65 mm Hg over higher ranges is suggested in adults 65 years old or older.
16No single universal hemodynamic target exists, and targets should be individualized.
17For CVP, noninvasive estimation can be made from jugular venous pulsation with the patient at 45°, using the height of jugular venous distention above the sternal angle, which is about 5 cm above the center of the right atrium.
18CVP can be measured invasively from an internal jugular or subclavian catheter, and it can also be estimated from a femoral venous site if intra-abdominal pressure is <12 mm Hg.
19Because respiration alters CVP, measurement should be taken at end-expiration; in mechanically ventilated patients this is just before inspiration begins, whereas in spontaneously breathing patients the respiratory pattern is reversed.
20If identifiable, the CVP should be measured at the end of the a wave, which is end-diastole.
21The physiological range of CVP is described as small, so precise measurement is important.
22CVP waveform components are described as: a wave = atrial contraction; c wave = buckling of the tricuspid valve into the right atrium at the onset of systole; x wave = fall in atrial pressure during atrial relaxation; y wave = decrease in atrial pressure at the onset of diastole when the atrioventricular valve opens and blood empties into the ventricle; v wave = venous refilling of the right atrium.
23Prominent a waves suggest reduced right atrial compliance, cannon a waves indicate atrioventricular dissociation, and a large y descent suggests restrictive right-heart physiology with little likelihood that CO will rise after a volume bolus.
24During spontaneous breathing, an inspiratory decrease in CVP > 2 mm Hg suggests fluid responsiveness, whereas an inspiratory increase in CVP is seen in cor pulmonale.
25If CVP rises by > 2 mm Hg during fluid infusion, this strongly suggests impending RV overload, and fluid infusion should be stopped while the cardiovascular state is reassessed; the two-to-five rule applies: stop the fluid challenge if ΔCVP is >5 at the end of the 10-minute bolus, and if ΔCVP is 2–5, wait another 10 minutes and stop if ΔCVP is then >2.
26CVP does not reliably reflect true RV loading because it is affected by pleural, intrathoracic, and intra-abdominal pressures and lung compliance; only transmural right atrial pressure adequately evaluates RV preload.
27CVP does not predict fluid responsiveness and should not be used alone to guide fluid administration.
28Specific CVP studies report limited predictive performance: CVP < 8 mm Hg had a positive predictive value of 47%; the highest predictive value across CVP 0–20 mm Hg was 66%; a gray-zone analysis found fluid response observed when CVP < 6 mm Hg and unlikely when CVP > 15 mm Hg; CVP > 10 mm Hg was considered high with no benefit from fluid administration, yet 25% of patients with CVP < 5 mm Hg were nonresponders.
29An older CVP target was 8–12 mm Hg, whereas current practice no longer targets fluid infusion to CVP goals.
30An elevated CVP is described as always abnormal, whereas a low CVP may be normal or may reflect hypovolemia.
31CVP is most useful when interpreted over time together with corresponding changes in cardiac output or a surrogate of blood flow.
32Cardiac output monitoring methods are indicator dilution, Doppler-derived blood flow measurement, pulse wave analysis, and bioimpedance/bioreactance.
33Indicator dilution includes pulmonary artery thermodilution, transpulmonary thermodilution, and lithium dilution; the common principle is a known bolus of indicator is injected and its downstream concentration-time curve is analyzed, with faster blood flow producing more rapid rise and downslope.
34Pulmonary artery thermodilution and transpulmonary thermodilution are described as the clinical gold standard for CO measurement.
35Pulmonary artery thermodilution can additionally provide RV ejection fraction and RV end-diastolic volume, while transpulmonary thermodilution can additionally provide global end-diastolic volume and extravascular lung water.
36Doppler-derived CO monitoring is described as low invasiveness but highly user dependent and not suitable for long-term use.
37Pulse wave analysis is presented as deriving flow information from the shape of the arterial pressure wave, including peripheral and even noninvasive pulse signals.
38Each CO method has its own tradeoff between invasiveness and exactness, and the desirable profile depends on the patient: low invasiveness and automation are favored in more stable perioperative use, whereas precision and associated parameters matter more in complex shock.
39Clinical utility requirements for a CO monitor include reliability, noninvasiveness, continuous real-time measurement, automation, user independence where possible, and ease of implementation.
40Echocardiography is described as a major bedside tool for hemodynamic assessment in critical care and cardiac surgery and can provide crucial diagnostic information in hemodynamic instability.
41Doppler echocardiography has replaced cardiac catheterization for hemodynamic assessment in most daily clinical purposes and has become the preferred method for this purpose.
42Echocardiography can help assess preload, pump function, afterload, valve function, ventricular function, systolic and diastolic function, pericardium, and adjacent vessels, integrating these into an overall hemodynamic picture.
43Its strength in monitoring is repeated bedside assessment over time and after clinical fluctuations or therapeutic changes.
44Echocardiography is not continuous, and information depends on image quality, which may be poor in supine, ventilated, unconscious patients, when other equipment interferes, or during active resuscitation.
45According to one ICU/OR echocardiography text, some intravascular pressures cannot be directly measured by echocardiography, including left atrial pressure, LV end-diastolic pressure, and systolic pulmonary artery pressure, but Doppler data can be used with the modified Bernoulli equation to calculate specific pressures.
46Left ventricular filling pressure or pulmonary capillary wedge pressure can be estimated by combining transmitral flow velocity from pulse-wave Doppler with tissue relaxation velocity from tissue Doppler imaging.
47Right atrial pressure is assessed indirectly by ultrasound.
48Echocardiographic SV can be calculated as cross-sectional area × VTI, CO = SV × HR, and LVOT assessment uses pulsed-wave Doppler with LVOT diameter measured in systole and area calculated as πr2.
49Sequential LVOT VTI alone is recommended for serial measurements, assuming LVOT diameter remains constant.
50After passive leg raising, an increase in LVOT VTI > 12% is described as highly sensitive and specific for volume responsiveness.
51Patients with normal SV typically have LVOT VTI > 20 cm.
52Echocardiography can diagnose pericardial effusion by showing echo-free space between parietal and visceral pericardium; RA collapse in early systole and RV collapse in early diastole with a distended IVC denote tamponade.
53For pulmonary artery catheterization, PAC uniquely enables direct measurement of SvO2, PAP, and PAWP, whereas central venous access permits ScvO2 but not these direct pulmonary measurements.
54Hemodynamic variables directly available from a PAC include mixed venous O2 saturation, cardiac output, intrapulmonary vascular pressures, and in some catheters RVEF; specialized catheters can also provide continuous SvO2, continuous CO, RV end-diastolic volume, and RV ejection fraction.
55PAC objectives are assessing LV or RV function, monitoring hemodynamic status, guiding pharmacologic and nonpharmacologic therapy, and providing prognostic information.
56Possible PAC indications in cardiovascular disease are myocardial infarction with cardiogenic shock, mechanical complications, or right heart failure; severe or progressive congestive heart failure; and primary pulmonary hypertension for diagnosis; many experts place PACs in severely ill patients with cardiogenic shock, but data supporting PAC use in severe heart failure are lacking.
57Potential perioperative indications include severely depressed LV systolic function with LVEF ≤0.30–0.35, LV diastolic dysfunction, impaired RV function, acute VSD, and support with IABP or other MCS.
58Indications include cardiogenic shock, mixed shock states, high-risk cardiac surgery, mechanical complications of STEMI including papillary muscle rupture and VSD, and RV infarction; when patients fail to respond to treatment, invasive monitoring becomes essential to tell failure of one ventricle from failure of both and so choose treatment.
59The same workbook lists absolute contraindications as right-sided endocarditis, atrial myxoma, tricuspid or pulmonary valve replacement, and high risk of dysrhythmias; relative contraindications are LBBB with 5% risk of complete heart block and tricuspid regurgitation.
60PAC insertion is described via an 8.5 Fr introducer sheath through the internal jugular, subclavian, or femoral vein, with the right internal jugular as the most direct route; from that site the pulmonary circulation is reached at 40–55 cm; most operators favour the right internal jugular, or else the left subclavian, as these routes ease passage into the pulmonary artery, and keep femoral or antecubital veins for when no other access is possible.
61Right jugular venous access is also described as preferred for bedside right-heart catheterization because the balloon-tipped catheter is naturally directed toward the pulmonary artery without fluoroscopy.
62Continuous monitoring of pulmonary artery pressure is advised to detect catheter migration and a wedged trace; if present, the catheter should be pulled back immediately.
63Local infection risk rises after 5 days and the need for the catheter should be reconsidered daily.
64For wedge pressure measurement, the balloon should be inflated slowly while watching the waveform, especially in elderly patients and those with pulmonary hypertension, and the trace should wedge only after ≥1.3 mL air fills the balloon.
65Wedge pressure should be measured at end expiration; for ventilated patients end expiration corresponds to the lowest reading, and during spontaneous breathing to the highest reading.
66PAWP cannot be higher than pulmonary artery diastolic pressure.
67Despite its comprehensive data, PAC use has not shown mortality benefit in critically ill or decompensated heart-failure populations, and its invasive nature and interpretation demands contribute to ongoing debate.