Recognition and diagnosis1Fluid responsiveness is often defined as a 10%–15% increase in cardiac output after intravenous fluid administration.
2Response to fluid administration is defined as a 10%–15% increase in stroke volume or cardiac output after a fluid challenge.
3For PLR specifically, a threshold of a 10% increase in stroke volume and/or cardiac output is described for defining fluid responsiveness.
4PLR can be performed by raising the legs to 45° for 30–90 seconds while monitoring a real-time stroke volume or cardiac output signal.
5Another description of PLR is to elevate the lower limbs to 45° from either a 45° semirecumbent position or from supine.
6With echocardiographic PLR, the head of bed is rapidly changed from 30–45° to 0° while the lower limbs are elevated to 30–45°, which transfers 250–350 mL of blood from the legs to the heart; cardiac output changes can then be assessed after 1–2 minutes.
7PLR-induced changes in cardiac output reliably predict fluid responsiveness regardless of ventilation mode and cardiac rhythm and can be recommended for routine assessment in most ICU patients; the effects should be measured directly on cardiac output, because judging them on arterial pressure, even pulse pressure, lowers sensitivity and increases false negatives.
8In critically ill patients, PLR has high diagnostic accuracy, with meta-analyses reporting an AUROC of 0.95.
9The classic fluid challenge is about 250 mL of colloid or crystalloid over 10 minutes with monitoring for clinical efficacy and safety; giving 4 mL/kg of crystalloids over 10 min identifies the most fluid responders, and the effect should ideally be assessed on cardiac output or its surrogates.
10The minimum IV fluid volume required to determine fluid responsiveness is 4 mL/kg over 10–15 min.
11The classical fluid challenge is described as 4 mL/kg over 5–15 min, whereas it is defined as 200 to 500 mL infused over 5–10 min with its effects assessed.
12A mini-fluid challenge is 100–150 mL, or 1–2 mL/kg over 1–5 min, and has reasonable validation for predicting volume responsiveness with less fluid accumulation; it is also defined as 50–100 mL of crystalloid over 1 min to predict response to a larger bolus, an approach that should be used with caution. The mini-fluid challenge is a fast infusion of a small volume of fluid, from 100 to 150 mL, but no recommendation is made on its use in patients with shock because the available data are scarce or heterogeneous.
13100 mL colloid over 1 minute with aortic blood flow measurement could predict fluid responsiveness.
14A mini-fluid challenge should probably not use <100 mL, because 50 mL was reported as unable to detect preload dependence; it is reserved for patients whose risk of fluid overload is not excessive, and when judged by LVOT VTI on echocardiography, the positivity threshold is near the reproducibility limit of ultrasound.
15Among dynamic arterial waveform predictors, variation in systolic pressure, pulse pressure, or stroke volume >10%–15% between inspiration and expiration suggests that IV fluid may increase stroke volume and cardiac output in mechanically ventilated patients who are not spontaneously breathing.
16For PPV, values of 13%–15% are strongly associated with volume responsiveness; however, PPV and SVV cannot be used in many circumstances, with false positives in spontaneous ventilation, cardiac arrhythmia, and perhaps RV failure, and false negatives with low tidal volume, low lung compliance, or a very high respiratory rate.
17PPV can be calculated as (maximum pulse pressure minus minimum pulse pressure) divided by mean pulse pressure, usually averaged over at least 3 breaths.
18For echocardiographic dynamic assessment during positive-pressure ventilation, ΔVTI >10% predicts fluid responsiveness, whereas respiratory VTI variation >20% is also used, applicable in mechanically ventilated patients with tidal volumes of at least 8 mL/kg and without arrhythmias or raised abdominal pressure.
19ΔVpeak >12% predicts fluid responsiveness.
20In mechanically ventilated patients with tidal volumes of at least 8 mL/kg and no arrhythmias or raised abdominal pressure, respiratory VTI variation >20% or peak aortic flow velocity variation >12% predicts fluid responsiveness.
21Respiratory variation in vena cava diameter is also used. ΔIVC >18% and ΔSVC >36% are given as cut-offs; however, it is suggested not to use changes in IVC diameter alone to assess fluid responsiveness in critically ill patients.
22In patients on positive-pressure ventilation, respiratory variation in IVC diameter >18% predicts fluid responsiveness.
23A lower threshold is that an IVC respiratory variation index of 12% predicts an increase in cardiac output >15%, while SVC collapsibility index ≥36% is also predictive.
24The end-expiratory occlusion test is described as indicating preload responsiveness if cardiac output increases by 5%.
25Ultrasound measures that have been proposed include IVC diameter, collapsibility, IVC size relative to the aorta, and distention with positive-pressure ventilation, as well as left ventricular cavity size and aortic flow velocity on transthoracic or transesophageal echocardiography.
26Echocardiographic criteria for overt hypovolemia are LV end-diastolic diameter <25 mm, systolic obliteration of the LV cavity, and LV end-diastolic area <5.5 cm2/m2; however, a large end-diastolic area does not prove adequate preload when the LV is impaired, and low vascular resistance, as in early sepsis, can empty the LV markedly without true hypovolemia.
27In true hypovolemia both LV systolic and diastolic areas are small, whereas in vasodilatory hypotension only the systolic LV area is small.
28Static measures perform poorly. CVP, PAOP, global end-diastolic volume, LV end-diastolic area/volume, and related filling-pressure measures are described as unreliable for predicting fluid responsiveness.
29CVP has an AUROC close to 0.5 for predicting fluid responsiveness.
30Most patients respond when CVP <8 mm Hg and only a few when CVP >12 mm Hg, although there are no clear cutoffs and Rivers et al. used a target CVP 8–12 mm Hg.
31Definitions of fluid responsiveness vary, and this limits comparison of methods.